*Operating voltage : 110 ? 240 V AC 50 ? 60 Hz
*Voltage inputs : 10 V DC ? 240 V AC 2 mA
*Max. cable length : 100 m
*Output : 12 V DC/18 mA, SELV,
No products in the cart.
Out of stock
*12-way binary input FIX1
*2 additional channels operable by buttons on the device, but without input, Free allocation of functions: switch/push button, dimming, blinds/roller blinds, counter, repeat telegram, sequences
RM2,404.33
Out of stock
*Operating voltage : 110 ? 240 V AC 50 ? 60 Hz
*Voltage inputs : 10 V DC ? 240 V AC 2 mA
*Max. cable length : 100 m
*Output : 12 V DC/18 mA, SELV,
There are no inquiries yet.
Logic Controller
spaceLYnk is the easiest way to build a complete Building Automation Solutions for commercial segments :
_ Complete Building Automation solution for Small and Medium building with a complete architecture including Light and Room Control (KNX, DALI Control), Metering (Modbus offer, Smartlink RTU and IP), and boiler management (SSL)
_ Complete Building Automation solution for Large Building with a complete architecture managed by SBO (BMS from Schneider Electric) and including Light and Room Control (KNX, DALI Control) and Metering (Modbus offer, Smartlink RTU and IP)
The KNX DALI gateway connects KNX to the DALI bus.
The gateway is a category I control device with an integrated DALI power supply for the ECGs (electronic ballasts / electronic control gear).
The device is a Single-Master Controller according to EN 62386 ed/1 and ed/2.
It is able to control DALI ECGs ed/1 and ed/2 -also mixed- but according to single-master controller it cannot support DALI-2 sensors like movement- and presence detectors, switches etc.
Described features are related to Firmware V3.1.3 or higher with DCA and ETS application 7310 most earlier delivered devices can be upgraded
It supports the switching and dimming of up to 64 ECGs in 16 groups and the control up to 16 scenes.
The 64 ECGs can be controlled individually or in groups.
Error messages of individual ECGs or each connected lamp can be transmitted to the KNX and visualised.
For independent control of up to 8 blind/roller shutter drives or for switching up to 16 loads via make contacts
The function of the blind or switching channels is freely configurable
All blind/switch outputs can be operated manually using push-buttons
For the control of independent 230 V AC drives via ABB i-bus? KNX.
The devices are designed for positioning blinds, roller shutters, awnings and other shading products as well as for controlling doors, windows and ventilation flaps. Additional auxiliary voltage is not needed.
To protect the drives, the output contacts are electromechanically locked against each other.
Push buttons are located at the front of the device to control the outputs e.g. during commissioning.
The current status of the output is displayed via LEDs.