Operating voltage : 230 _ 240 V AC 50 _ 60 Hz
KNX output : 1 line with integrated throttle drive
Nominal current KNX : 160 mA
Certification : KNX Certified
No products in the cart.
Out of stock
Power-supplying and monitoring of the KNX system voltage
160 mA supply voltage
30 V DC auxiliary supply
Reset key for 20 sec
bus reset Continuous short-circuit protection
RM759.22
Out of stock
Operating voltage : 230 _ 240 V AC 50 _ 60 Hz
KNX output : 1 line with integrated throttle drive
Nominal current KNX : 160 mA
Certification : KNX Certified
There are no inquiries yet.
For controlling DALI devices via the ABB i-bus?.
Two DALI output for up to 2×64 DALI slaves.
DALI power supply is integrated.
Control and status feedback is carried out via KNX per DALI slave (2×64), with groups (2×16), together in broadcast or per scenes (2×16). Extensive fault and error messages are available Self-contained emergency converter (2×64) acc.
EN 62386-202 will be supported. By means of KNX and emergency converter different emergency tests (e.g. function and duration test) can be triggered.
Feedback is sent. Slave-, staircase-, force-, block- and scene- function are integrated.
DALI telegram rate can change.
For controlling DALI devices via the ABB i-bus?
One DALI output for up to 64 DALI slaves. DALI power supply is integrated
Control and status feedback is carried out via KNX per DALI slave (64), with lighting groups (16), together in broadcast or per scenes (16)
Extensive fault and error messages are available Self-contained emergency converter (64) acc. EN 62386-202 will be supported
By means of KNX and emergency converter different emergency tests (e.g. function and duration test) can be triggered
Feedback is sent. Slave-, staircase-, force-, block- and scene- function are integrated. DALI telegram rate can change.
Uses potential free contacts to switch 12 independent electrical loads via the ABB i-bus?
Manual operation and display of the switching state of the contacts
The 10AX device is especially suited for loads with high surge currents e.g. flourescent lighting (AX) acc
EN 60669.
The KNX DALI gateway connects KNX to the DALI bus.
The gateway is a category I control
device with an integrated DALI power supply for the ECGs (electronic ballasts / electronic control gear).
The device is a Single-Master Controller according to EN 62386 ed/1 and ed/2.
It is able to control DALI ECGs ed/1 and ed/2 -also mixed- but according to single-master controller it cannot support DALI-2 sensors like movement- and presence detectors, switches etc.
Described features are related to Firmware V3.1.3 or higher with DCA and ETS application 7310 most earlier delivered devices can be upgraded
It supports the switching and dimming of up to 64 ECGs in 16 groups and the control up to 16 scenes.
The 64 ECGs can be controlled individually or in groups. Error messages of individual ECGs or each connected lamp can be transmitted to the KNX and visualised.