Explosion Proof Lighting & Equipment
Showing 1–10 of 20 results
-
Explosion Proof, Indoor Lighting, Lamp, Outdoor Lighting
EATON – CROUSE HINDS cLLK 07…series Explosion Proof Fluorescent Lighting For ZONE 1, 21, 2 & 22 Hazardous Area.
Explosion Proof, Indoor Lighting, Lamp, Outdoor LightingEATON – CROUSE HINDS cLLK 07…series Explosion Proof Fluorescent Lighting For ZONE 1, 21, 2 & 22 Hazardous Area.
EATON-CROUSE HINDS cLLK 07…series Explosion Proof Fluorescent Lighting For ZONE 1, 21, 2 & 22 Hazardous Area.
The cLLK 07 Ex-protected light fittings for bi-pin fluorescent lamps are fitted with an electronic ballast and conform
to the ATEX Directive 94/9/EG. The modern electronic ballast according to the latest standards (IEC 60079-7: 2006)
allows a safe and economical operation of bi-pin fluorescent lamps G13 according to IEC 60081. Lamps reaching its
end of life will be monitored and securely switched off (EOL-effect). Due to the standard dual channel architecture (with
double lamp fittings) if one fluorescent lamp fails, the other fluorescent lamp will independently stay in operation. The
standard single-sided throughwiring in connection with the variety of possi -bilities offers a cost efficient installation.
Doublesided lock with 10 or 20 latch points allows the protective bowl to be hingeable on both sides meaning the
fitting can be mounted without having to pay attention to which side is the right side. Automatic switch built as a safety
disconnector according to EN 60947 (IEC 664) with an automatic switch ensuring the disconnection of all exposed
components when the fitting is opened.SKU: n/a -
Explosion Proof, Indoor Lighting, Lamp, Outdoor Lighting
EATON – CROUSE HINDS cLLK 07…series Explosion Proof Fluorescent Lighting For ZONE 1, 21, 2 & 22 Hazardous Area.
Explosion Proof, Indoor Lighting, Lamp, Outdoor LightingEATON – CROUSE HINDS cLLK 07…series Explosion Proof Fluorescent Lighting For ZONE 1, 21, 2 & 22 Hazardous Area.
EATON-CROUSE HINDS cLLK 07…series Explosion Proof Fluorescent Lighting For ZONE 1, 21, 2 & 22 Hazardous Area.
The cLLK 07 Ex-protected light fittings for bi-pin fluorescent lamps are fitted with an electronic ballast and conform
to the ATEX Directive 94/9/EG. The modern electronic ballast according to the latest standards (IEC 60079-7: 2006)
allows a safe and economical operation of bi-pin fluorescent lamps G13 according to IEC 60081. Lamps reaching its
end of life will be monitored and securely switched off (EOL-effect). Due to the standard dual channel architecture (with
double lamp fittings) if one fluorescent lamp fails, the other fluorescent lamp will independently stay in operation. The
standard single-sided throughwiring in connection with the variety of possi -bilities offers a cost efficient installation.
Doublesided lock with 10 or 20 latch points allows the protective bowl to be hingeable on both sides meaning the
fitting can be mounted without having to pay attention to which side is the right side. Automatic switch built as a safety
disconnector according to EN 60947 (IEC 664) with an automatic switch ensuring the disconnection of all exposed
components when the fitting is opened.SKU: n/a -
Explosion Proof, Explosion Proof Beacon Light Fitting, Explosion Proof LED Lighting, Indoor Lighting, Lamp, LED, Outdoor Lighting
Explosion Proof Beacon Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area.
Explosion Proof, Explosion Proof Beacon Light Fitting, Explosion Proof LED Lighting, Indoor Lighting, Lamp, LED, Outdoor LightingExplosion Proof Beacon Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area.
COELBO EVA…series Explosion Proof Beacon Light Fitting
● Body in Aluminum light alloy.
● Safety globe: tempered borosilicate.
● Reduced dimensions by virtue of the fixture type EVA 50;
they are normally associated to alarm and signalling
systems, either fixed or mobile.● Complete with blinking Xenon flash lamp.
● Connection E27.
● Power Supply 12V / 24V d.c./ a.c..● Continuous duty.
Optional :
– Wire guard in Stainless Steel AISI 304.
– Painting RAL 3000.
– Power Supply 125 or 230 VAC.
– Signalling colors (Light Blue, White, Yellow, Orange, Red,
Green).– Cable entries NPT ANSI B1.20.1 (N) or Metric ISO 262 (M).
#ExplosionProofBeaconLight
#ExplosionProofWarningLight
#ExplosionProofLEDLights
SKU: n/a -
Explosion Proof, Indoor Lighting, Lamp, LED, Outdoor Lighting
Explosion Proof Fluorescent Light Fitting For ZONE 2 & 22 Hazardous Area
Explosion Proof, Indoor Lighting, Lamp, LED, Outdoor LightingExplosion Proof Fluorescent Light Fitting For ZONE 2 & 22 Hazardous Area
Schuch Quality – Your advantage:
• A high-quality chemically resistant light fitting of a sturdy design, best suitable for a longtime application in industrial areas
– housing made from glass fibre reinforced polyester resin of a high impact resistance, wall thickness: 2 mm
– injection moulded diffuser from highly shock resistant polycarbonate, resistance
impact: 16 Nm
– captive clips made fom stainless steel
– shock and earth-quake tested (by TÜV)
– wide range of Permissible ambient temperature from -20°C to +40°C
(50°C on request)
• “End-of-life swiching-off system” i.e. at the end of its life a fluorescent tube
is safely switched off
• Best suitable for installation and maintenance purpose ensuring simultaneously a high safety of continuous operation
– the diffuser is hinged on one side and can be suspended, the reflector can be suspended for quick
mains connection and lamp inserting/replacement
– quick and cost saving wiring in a continuous row installation thanks to a looping facility on one small
end of the housing (special version)
• High flexibility and wide range of application thanks to a great variety of equipment
– ATEX certification for gas and dust hazardous areas (ZONES 2 and 22)
– with electronic ballast or low loss conventional ballast
– for T16, T26 and T38 lamps
– for outdoor application at high ambient temperatures, for high installation, as emergency illumination etc.
• Excellent light distribution and glare limitation thanks to the diffuser with its light technically optimized internal prismsSKU: n/a -
Explosion Proof, Explosion Proof Highbay, Indoor Lighting, Outdoor Lighting
Explosion Proof Highbay Light Fitting For Hazardous Material Storage Warehouse
Explosion Proof, Explosion Proof Highbay, Indoor Lighting, Outdoor LightingExplosion Proof Highbay Light Fitting For Hazardous Material Storage Warehouse
Application :
• For use in corrosive, harsh, hazardous applications such as chemical, petrochem,
marine, power generation, pharmaceutical, or food processing plants• Electro-Reg® ballast provides long life, high lumen maintenance metal halide
light source for low operating and maintenance costs• Mogul base socket
• Cover selection of rigid and fl exible pendant, ceiling, wall and 25° stanchion in
varying threaded NPT entries• Minimum starting temp of -20°F for MV/MH and -40°F for HPS
• Copper-free (<0.4%) aluminum housing, cover and guard with Lektrocote®
powder polyester paint fi nish• Optic choices of impact resistant glass globe, sym./asym. glass refractors,
dome/angle FRP refl ector, 19” enclosed refl ector, and polycarbonate enclosed
low bay• Modular design permits selection of cover, body, globe, guard and refl ector
• UL844 Standard: Class I, Div. 2, Groups A,B,C,D; Class II, Div. 1/2, Groups E,F,G;
Class III, Div. 1/2• UL 1598A Marine Outdoor; NEMA 4X and IP66 with K-G globe; 40°C ambient listed; UL1598 Wet Location
#ExplosionProofHighbay
#ExplosionProofLighting
SKU: n/a -
Electrical & Wiring Accessories, Explosion Proof, Indoor Lighting, LED, Outdoor Lighting
Explosion Proof LED Light Fitting For ZONE 2 & 22 Hazardous Area.
Electrical & Wiring Accessories, Explosion Proof, Indoor Lighting, LED, Outdoor LightingExplosion Proof LED Light Fitting For ZONE 2 & 22 Hazardous Area.
SCHUCH nD866…series ExLed2 latest LED technology.
With luminous flux up to 9,210 lm and luminous efficacy up to 126 lm/W, the light fittings are not only extremely powerful but also highly efficient compared to competitive products.
The light fittings are available in 2 versions:
Energy optimized versions as substitute for EX linear luminaires with conventional lamps up to 2 x 58W and luminous flux optimized versions for areas that require high level of illumination. In addition, the customer can also chose between clear and frosted diffuser.
The frosted diffuser offers excellent glare limitation as well as comfortable light perception due to the homogeneous illumination – no single light points are visible, whereas the clear diffuser is particularly suitable for areas that require maximum luminous flux and high illumination levels.
Furthermore, the completely newly developed light fitting offers various unique features:
High colour rendering CRI>80 for installation in almost all work spaces in accordance with relevant national workplace guidelines.
Applicable at ambient temperatures between -30°C and +40°C / +60°C , depending on version.
Robust enclosure to avoid mechanical or electrostatic impact to the LED modules – provided through sandwich-design of diffuser and reflector
Easy to install due to an outer mounting system for variable mounting point distances.
The light fittings are also available with DALI-interface (optional).
With the new series e 866… SCHUCH now offers its customers the possibility to benefit from the advantages of the LED technology even in hazardous areas, where T8-flourescent tubes dominated so far.SKU: n/a -
Explosion Proof, Indoor Lighting, LED, Outdoor Lighting
Explosion Proof LED Linear Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area.
Explosion Proof, Indoor Lighting, LED, Outdoor LightingExplosion Proof LED Linear Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area.
SCHUCH e865…series Explosion Proof LED Linear Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area.
Your Advantage:
• LED modules with innovative encapsulation.
• Explosion Group IIC, hence suitable for atmospheres with hydrogen and acetylene.
• Highest efficiency with luminous efficacy up to 147lm/W
• Homogeneous illumination by using frosted diffusers (versions e865F..) no particular light points.
visible, comfortable perception of light, brilliant glare limitation
• High colour reproduction Ra typically 80, according to the workplace guide lines suitable for nearly all plant locations.
• Reflector and cover in sandwich design to protect the LED-Modules from mechanical or electrostatic damages due to accidential contact..
• Version with higher luminous flux for areas where higher illumination is needed.
• For high ambient temperatures up to +70°C depending on version.
• External mounting system for variable mounting distances and easy installation (retaining clips HK865 P).
• Lower maintenance and downtime costs due to long maintenance intervals.
• ECG and reflector with LED-modules replacable by qualified personnel on-site.SKU: n/a