[vc_row][vc_column] KNX power supplies 320 mA generate and monitor the KNX system voltage (SELV). The bus line is decoupled from the power supply by an integrated choke. The voltage output is short-circuit and overload protected. The two-color LED indicates device output status. With two-coloured status indicator and wide range input from 85?265 V AC, 50/60 Hz. KNX power supplies 640 mA generate and monitor the KNX system voltage (SELV). The bus line is decoupled from the power supply by an integrated choke. The voltage output is short-circuit and overload protected. The two-color LED indicates device output status. Device type SV/S 30.640.3.1 has an additional 30 V DC short-circuit and overload protected voltage output that can be used to power an additional bus line (in combination with a separate choke). With two-coloured status indicator and wide range input from 85?265 V AC, 50/60 Hz. The KNX DALI gateway connects KNX to the DALI bus. The gateway is a category I control The device is a Single-Master Controller according to EN 62386 ed/1 and ed/2. It supports the switching and dimming of up to 64 ECGs in 16 groups and the control up to 16 scenes. The 64 ECGs can be controlled individually or in groups. Error messages of individual ECGs or each connected lamp can be transmitted to the KNX and visualised. LOGO! 12/24RCE, logic module, disp PS/I/O: 12/24VDC/relay, 8 DI (4AI)/4DO, memory 400 blocks, modular expandable, Ethernet, integr. web server, data log, user-defined Web pages, standard microSD card for LOGO! Soft Comfort V8 or higher, older projects executable LOGO! 230RCE,logic module, display PS/I/O: 115V/230V/relay, 8 DI/4 DO, memory 400 blocks, modular expandable, Ethernet, integr. web server, data log, user-defined Web pages, standard microSD card for LOGO! Soft Comfort V8 or higher, older projects executable LOGO! SOFT Comfort V8, single license for 1 installation E-SW, SW and documentation on DVD, 6 languages, executable on Windows XP, 7, 8, 10 (32- and 64-bit), Mac OSx 10.7 Lion to incl. Mac OSx El Capitan, Linux SUSE 11.3, SP3, K 3.0.76 Pumphead with SS bolts, brackets, hose clamps & Peak pumping speed: SCHUCH e840…series Explosion Proof LED Linear Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area. SCHUCH e865…series Explosion Proof LED Linear Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area. Your Advantage: EATON’s Crouse-Hinds series HLL linear LED light fitting is constructed with an aluminium housing and high-impact resistant polycarbonate cover, providing extreme durability and reliability in Zone 1, 2, 21 and 22 hazardous areas. SCHUCH nD8301 / nD8302..series Explosion Proof LED High Bay Light Fitting For ZONE 2 & 22 Hazardous Area. Product highlights: This item will take 7-14 business days to ship, pre-prder not ready stock item Panasonic Air-e Ceiling Mount nanoe™X Generator FV-15CSD1NAH – Inhibits Virus & Bacteria **BRAND NEW & 100% ORIGINAL VERSION ** ⚙️ Specification • nanoe™X Purification • Silent Operation • Low Power Consumption • Easy Installation • Contemporary Design • Compact Size • Inhibit Virus and Bacteria • Deodorization • Hydrate Skin and Hair EATON-CROUSE HINDS cLLK 07…series Explosion Proof Fluorescent Lighting For ZONE 1, 21, 2 & 22 Hazardous Area. The cLLK 07 Ex-protected light fittings for bi-pin fluorescent lamps are fitted with an electronic ballast and conform EATON-CROUSE HINDS cLLK 07…series Explosion Proof Fluorescent Lighting For ZONE 1, 21, 2 & 22 Hazardous Area. The cLLK 07 Ex-protected light fittings for bi-pin fluorescent lamps are fitted with an electronic ballast and conformLighting Control System
ABB Power Supply 320mA
ABB Power Supply 640mA
ABB Line Coupler
device with an integrated DALI power supply for the ECGs (electronic ballasts / electronic control gear).
It is able to control DALI ECGs ed/1 and ed/2 -also mixed- but according to single-master controller it cannot support DALI-2 sensors like movement- and presence detectors, switches etc.
Described features are related to Firmware V3.1.3 or higher with DCA and ETS application 7310 most earlier delivered devices can be upgradedProgrammable Logic Controller (PLC)
Siemens LOGO! 12/24RCE, 8DI(4HSI,4AI) 4RO, V8.2
Siemens LOGO! 230RCE (AC/DC), 8IN 4RO, V8.2
Siemens LOGO! SOFT Comfort V8.2.1
Pumps
Watson Marlow Watson Marlow Bredel APEX 15 Hose Pump
Lubricant
With Galv Steel Support
High Pressure Rotor (4-8 Bar)
Pump Element : F-NBR
Sanitary Connectors, SS316 Tri-Clamp 3/4″
Flowrate : 197 L/Hr (36 RPM) @ 50 Hz
Min Flow : ~44L/H (8RPM) @ 12 HzAgilent IDP15 Scroll Pump, Std
60 Hz: 256 L/m, 15.4 m3/hr
50 Hz: 214 L/m, 12.8 m3/hr
Media:Not suitable for use with corrosive, explosive or particulate forming gases
Ultimate pressure:10 x 10−3 Torr (13.3 x 10−3 mbar)
Maximum inlet pressure:1.0 atmosphere (0 psig)
Maximum outlet pressure: 6.5 psig
Inlet connection:NW25
Exhaust connection: NW16LED
SCHUCH e840…series Explosion Proof LED Linear Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area.
SCHUCH e840…series Explosion Proof LED Linear Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area.
• Extremly robust construction of housing and diffuser.
• Comfortable central locking mechanism for easy maintenance.
• Innovative encapsulation with high transmission rate
• Homogene lighting distribution by frosted anti-glare modules-protecting the LEDs as well of ESD and mechanical damage. No individual light points visible, comfortable perception of light, brilliant glare limitation.
• High colour rendering index CRI > 80, according to the workplace guide lines suitable for nearly all plant locations.
• ECG and reflector with LED-modules replacable by qualified personnel on-site.Explosion Proof LED Linear Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area.
Explosion Proof LED Linear Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area.
• LED modules with innovative encapsulation.
• Explosion Group IIC, hence suitable for atmospheres with hydrogen and acetylene.
• Highest efficiency with luminous efficacy up to 147lm/W
• Homogeneous illumination by using frosted diffusers (versions e865F..) no particular light points.
visible, comfortable perception of light, brilliant glare limitation
• High colour reproduction Ra typically 80, according to the workplace guide lines suitable for nearly all plant locations.
• Reflector and cover in sandwich design to protect the LED-Modules from mechanical or electrostatic damages due to accidential contact..
• Version with higher luminous flux for areas where higher illumination is needed.
• For high ambient temperatures up to +70°C depending on version.
• External mounting system for variable mounting distances and easy installation (retaining clips HK865 P).
• Lower maintenance and downtime costs due to long maintenance intervals.
• ECG and reflector with LED-modules replacable by qualified personnel on-site.Explosion Proof Linear LED Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area
Explosion Proof Linear LED Light Fitting For ZONE 1, 21, 2 & 22 Hazardous Area
The use of high-quality LED chips, coupled with our exten sive experience in thermal mana gement of electrical components in hazardous areas, ensures long service life of the HLL series. The extended temperature range of -40 °C to +55 °C allows these luminaires to be used in a wide range of ambient conditions where an explosive atmosphere is to be expected.
With its long service life, low maintenance requirements and low energy consumption, the HLL provides superior performance with a competitive payback versus traditional fluorescent fixtures.
The luminaire series is also available as a single-battery emergency light fitting HLL-EM for ambient temperatures from -25 °C to +55 °C.SCHUCH nD8301 / nD8302…series Explosion Proof LED High Bay Light Fitting For ZONE 2 & 22 Hazardous Area.
SCHUCH nD8301 / nD8302…series Explosion Proof LED High Bay Light Fitting For ZONE 2 & 22 Hazardous Area.
• High efficient by use of top-quality mid-power LEDs.
• Extremely high lifetime even at the maximum permissible ambient temperature.
• Optimized thermo management due to direct mounting of the LED modules to the housing and separate housings for ECG- and LED-moules, huge heat sink with excellent heat dissipation.
• DALI interface (standard) for dimmed operation.
• Colour rendering index CRI > 80.
• Uniform illumination due to the „Multi-Layer Technology“ i.e. every individual LED illuminates the whole surface, the light curves of the individual LED are overlapping. No dark zones if any single LED would fail. The uniformity of the illumination is kept.
• Future proof by using standardized LED-modules (Zhaga).Recently Viewed
Panasonic Air Purifier Air-e Ceiling Mount nanoe™X Generator FV-15CSD1NAH – Inhibits Virus & Bacteria
Panasonic Air Purifier Air-e Ceiling Mount nanoe™X Generator FV-15CSD1NAH – Inhibits Virus & Bacteria
EATON – CROUSE HINDS cLLK 07…series Explosion Proof Fluorescent Lighting For ZONE 1, 21, 2 & 22 Hazardous Area.
EATON – CROUSE HINDS cLLK 07…series Explosion Proof Fluorescent Lighting For ZONE 1, 21, 2 & 22 Hazardous Area.
to the ATEX Directive 94/9/EG. The modern electronic ballast according to the latest standards (IEC 60079-7: 2006)
allows a safe and economical operation of bi-pin fluorescent lamps G13 according to IEC 60081. Lamps reaching its
end of life will be monitored and securely switched off (EOL-effect). Due to the standard dual channel architecture (with
double lamp fittings) if one fluorescent lamp fails, the other fluorescent lamp will independently stay in operation. The
standard single-sided throughwiring in connection with the variety of possi -bilities offers a cost efficient installation.
Doublesided lock with 10 or 20 latch points allows the protective bowl to be hingeable on both sides meaning the
fitting can be mounted without having to pay attention to which side is the right side. Automatic switch built as a safety
disconnector according to EN 60947 (IEC 664) with an automatic switch ensuring the disconnection of all exposed
components when the fitting is opened.EATON – CROUSE HINDS cLLK 07…series Explosion Proof Fluorescent Lighting For ZONE 1, 21, 2 & 22 Hazardous Area.
EATON – CROUSE HINDS cLLK 07…series Explosion Proof Fluorescent Lighting For ZONE 1, 21, 2 & 22 Hazardous Area.
to the ATEX Directive 94/9/EG. The modern electronic ballast according to the latest standards (IEC 60079-7: 2006)
allows a safe and economical operation of bi-pin fluorescent lamps G13 according to IEC 60081. Lamps reaching its
end of life will be monitored and securely switched off (EOL-effect). Due to the standard dual channel architecture (with
double lamp fittings) if one fluorescent lamp fails, the other fluorescent lamp will independently stay in operation. The
standard single-sided throughwiring in connection with the variety of possi -bilities offers a cost efficient installation.
Doublesided lock with 10 or 20 latch points allows the protective bowl to be hingeable on both sides meaning the
fitting can be mounted without having to pay attention to which side is the right side. Automatic switch built as a safety
disconnector according to EN 60947 (IEC 664) with an automatic switch ensuring the disconnection of all exposed
components when the fitting is opened.
Lighting Control System, Power Supply
SKU: SV/S 30.320.1.1
Lighting Control System, Power Supply
SKU: SV/S 3.640.3.1
Controller, Lighting Control System
SKU: LK/S 4.1
Controller, Programmable Logic Controller (PLC)
SKU: 6ED1052-1MD08-0BA0
Controller, Programmable Logic Controller (PLC)
SKU: 6ED1052-1FB08-0BA0
Programmable Logic Controller (PLC), Software
SKU: 6ED1058-0BA08-0YA1
Pumps
SKU: 28-015065
Pumps, Scroll Pumps
SKU: X3815-64000
Explosion Proof, Indoor Lighting, LED, Outdoor Lighting
Explosion Proof, Indoor Lighting, LED, Outdoor Lighting
SKU: n/a
Explosion Proof, Indoor Lighting, LED, Outdoor Lighting
Explosion Proof, Indoor Lighting, LED, Outdoor Lighting
SKU: n/a
Explosion Proof, Indoor Lighting, Lamp, LED, Outdoor Lighting
Explosion Proof, Indoor Lighting, Lamp, LED, Outdoor Lighting
SKU: n/a
Explosion Proof, Indoor Lighting, Lamp, LED, Outdoor Lighting
Explosion Proof, Indoor Lighting, Lamp, LED, Outdoor Lighting
SKU: n/a
Air Purifier
Air Purifier
SKU: fmk-panasonic-FV-15CSD1NAH
Explosion Proof, Indoor Lighting, Lamp, Outdoor Lighting
Explosion Proof, Indoor Lighting, Lamp, Outdoor Lighting
SKU: n/a
Explosion Proof, Indoor Lighting, Lamp, Outdoor Lighting
Explosion Proof, Indoor Lighting, Lamp, Outdoor Lighting
SKU: n/a
Smartphones
Laptops & Computers
-
Lighting Control System, Sensor
Steinel IR Quattro SLIM EAN 4007841058494
Genuine 16 m2 of presence detection concentrated on 4 mm
Control PRO IR Quattro SLIM KNX presence detector for indoors
ideal for small offices, store, service and utility rooms, washrooms and WCs, for mounting at a height of up to 4 m, with digital BUS interface for controlling 4 lighting channels and HVAC.
SKU: so-stn-1